FIBRE OPTICS CABLES > MICROMODULE > MULTI-TUBE

2F-48F Single Sheath Fan Out Tight Buffered
Unarmoured Optical Fibre Cable

Ipsum

Typical Cross section of 24 Fibre

Cable Construction Details

  • LSZH Tight Buffer.
  • High Modulus, Aramid yarn as strength member below inner sheath.
  • UV Stabilized, LSZH Outer sheath, black.
FIBRE COUNT TIGHT BUFFER DIAMETER (μm)Nominal DIAMETER (mm) Nominal WEIGHT (Kg./Km) Nominal TENSILE STRENGTH (N) BENDING RADIUS (mm) TEMPERATURE RANGE
(IEC 60794-1-2-F1)
Installation Operation Installation Operation Installation Operation
2 900 4.8 20 800 500 10D 20D -5°C to +60°C -40°C to +70°C
4 900 5.2 24 800 500 10D 20D -5°C to +60°C -40°C to +70°C
6 900 5.7 28 800 500 10D 20D -5°C to +60°C -40°C to +70°C
8 900 6.2 32 800 500 10D 20D -5°C to +60°C -40°C to +70°C
12 900 7.0 42 800 500 10D 20D -5°C to +60°C -40°C to +70°C
16 900 7.5 48 1000 600 10D 20D -5°C to +60°C -40°C to +70°C
24 900 8.8 65 1500 700 10D 20D -5°C to +60°C -40°C to +70°C
32 900 9.5 72 1500 700 10D 20D -5°C to +60°C -40°C to +70°C
36 900 9.8 78 1700 800 10D 20D -5°C to +60°C -40°C to +70°C
48 900 10.8 94 2000 1000 10D 20D -5°C to +60°C -40°C to +70°C

Fibre & Micro Module Colour Coding

Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
*For Fibre Count 12F We provide the above colour code.
*For Higher Fibre count we provide contrast dot marking of above colour code.

Special Features

  • 900 Microns Tight buffered fibres support fast field installations.
  • Reduce installation time and costs.
  • Easy jacket removal using standard tools.
  • Flexible and Fire retardant Inner & outer sheath with aramid yarns and Glass Yarn as tensile elements helps in easy installation in space constrained areas.
  • LSZH sheath makes cable suitable for higher fire safety requirement.
  • Small cable diameter & lightweight.
  • Requires no grounding or bonding due to all‑dielectric construction.

Drum Length

  • 2000/ 4000meters ± 5%

Mechanical Characteristics

Kink Resistance (mm) [IEC 60794-1-2-E10] 10 x D, D = Cable Diameter
Impact Resistance (Nm) [IEC 60794-1-2-E4] Height 0.5 meters,
Weight = 0.5 Kg, 3 Nos
Crush Resistance (N) [IEC 60794-1-2-E3A] 500 N [100 X 100 mm] for 60 sec
Torsion Resistance [IEC 60794-1-2-E7] 10 Cycle [± 180°] 1 Kg Weight,
Length under Test‑2 meters
Repeated Bending [IEC 60794-1-2-E6] 30 Cycle, r = 20 X D,
1 Kg Load, D = Cable Diameter